Santa Barbara · Generator Installation and Service
Isla Vista Generators
Backup power and rental units for student housing, property managers and campus-adjacent businesses in Isla Vista.

Isla Vista · Generator Installation and Service
Multi-Unit Housing And Campus-Adjacent Work
Almost everything we do in Isla Vista is for somebody who owns a building rather than lives in one. Property managers here run dozens of units across several addresses, and an outage means elevators, lighting in shared stairwells, gate access and, in the newer buildings, the fire alarm panel and the emergency lighting. That last category is not optional: life safety systems have to hold up under code, and the way they do that is with a properly maintained standby system.
For the buildings that already have one, the work is nearly always generator repair and annual servicing rather than new equipment. These units live outdoors, half a mile from the surf, get exercised on a timer nobody checks and then get asked to carry a real load once every few years. Batteries, block heaters, coolant and transfer switch contacts are what actually fail, and all four are cheap compared to a failed start during an inspection.
New installs here are usually driven by a remodel or a change of use, and the sizing conversation starts with which circuits genuinely have to stay live. A backup generator covering egress lighting, the alarm panel, one elevator and the common-area refrigeration is a much easier project to permit and pay for than one trying to carry every apartment at once.
The businesses on Embarcadero and Pardall have the same problem restaurants have everywhere, which is refrigeration. We rent units for planned utility shutdowns and deliver on short notice for unplanned ones, and a generator rental for a weekend is a great deal cheaper than replacing a cooler full of stock.

Generators In Isla Vista
Everything we install, service and rent in Isla Vista and across Santa Barbara County.
🏠
Whole House Generators
Permanently installed home standby generators that start themselves within seconds of an outage and run the house until the grid comes back.
🔌
Backup Generators
Standby and emergency backup systems that keep the essential circuits alive through storms, wind events and public safety power shutoffs.
🏭
Industrial Generators
Three-phase diesel and gas gensets from 100kW upward for agriculture, wineries, water systems, cold storage and manufacturing.
🏢
Commercial Generators
Standby systems for restaurants, medical and dental offices, hotels, grocery, retail and managed property, with service contracts to match.
🔧
Generator Repair
Diagnostics, emergency callouts and annual maintenance on residential, commercial and industrial units of any brand.
⚡
Generator Rentals
Portable, towable and trailer generators from 5kW to 500kW, delivered, connected and fuelled for construction, events, film and industry.
The crew that covers Isla Vista works the rest of the county on the same schedule for Santa Barbara generator installation, so the sizing method, the permit process and the service rates are identical here to anywhere else on our routes. Call: (805) 572-7405
Frequently Asked Questions
What size generator do I need for my home?
It comes from what has to run, not from square footage. A typical Santa Barbara home with gas heat and one air conditioner is comfortable on 18kW to 22kW. Add a second air conditioner, a pool, an EV charger, all-electric cooking or a well pump and you are into 26kW and above. The figure that usually sets the minimum is the starting current of the largest motor, since that is the moment a generator either holds or drops the load. We size on site and it takes about half an hour.
What is the difference between a portable and a standby generator?
A portable unit is rolled out, started by hand, refuelled from cans and connected through a manual transfer switch or interlock. A standby unit is bolted to a pad, connected to natural gas or propane, and started automatically by a transfer switch seconds after the utility fails, whether or not anyone is home. Portables suit an occasional short outage. Standby units are the answer where outages are long, frequent or expensive, which describes most of this county.
Natural gas, propane or diesel: which fuel is best?
Natural gas wherever the main reaches, because there is no tank, no deliveries and effectively unlimited runtime. Propane on rural parcels without a main, since it stores for years and a 500 gallon tank covers a week of running comfortably. Diesel above roughly 100kW, where its output per gallon and stamina under sustained load make it the standard for industrial and rental equipment. Propane derates an engine slightly compared with natural gas, which we allow for when sizing.
Which generator brands do you install and service?
We are factory trained on Generac, Kohler, Cummins and Champion and carry out warranty work on all four. Generac has the widest parts network in the country and leads the residential market. Kohler generators tend to have quieter enclosures at the same rating. Cummins builds the engines behind much of the commercial and industrial market. Champion sits at the accessible end of the price range. We also service Onan and older equipment we did not install.
How much does a whole house generator cost installed?
Between $5,000 and $15,000 for a complete installation in Santa Barbara County, covering the unit, the pad, the transfer switch, the gas work, the permit and commissioning. A critical-circuit system on a straightforward site is at the bottom of that band; a 26kW unit with a service-rated switch and a long gas run is at the top. We quote one flat number after a site visit rather than a headline price with additions.
Do you offer financing?
Yes, through the manufacturer programs and through our own lender, with terms that generally run from three to ten years depending on the amount. Most residential installations work out to a monthly payment in the same range as a phone bill, which is usually a more useful way to look at it than the total. We can put the numbers in front of you at the estimate rather than sending you away to work it out.
Does a standby generator add value to a house?
Agents and appraisers on the South Coast generally put a properly installed, permitted standby system at somewhere around 3 to 5 percent of home value, and it is a genuine selling point in areas that see public safety power shutoffs. Two conditions matter: the installation has to have been permitted and inspected, and there has to be a maintenance record. An unpermitted unit is a negotiating problem during escrow rather than an asset.
How long will a generator run during an outage?
On natural gas, as long as the outage lasts, since the fuel keeps arriving. On propane, a 250 gallon tank runs a mid-size home roughly two to three days at typical load and a 500 gallon tank comfortably covers a week. On diesel, runtime follows tank size, and a 100kW set with a 200 gallon base tank runs somewhere around a day and a half at half load before it wants refuelling.
How often does a generator need servicing?
Annually for a residential standby unit, or every 100 to 200 running hours if that comes first, with an early first service after commissioning. Commercial emergency systems are exercised monthly and given a documented annual test at rated load. Skipping the annual visit is the usual reason a warranty claim gets refused, and stale fuel and dead batteries are the two failures it exists to catch.
Need power that stays on?
Tell us the property and what has to keep running, and we will come back the same day with a free estimate and a flat installed price.
Or call us now: (805) 572-7405